SourcingAI

Wireless fire alarm system

I have found results from10000+products and4000+suppliers aboutWireless fire alarm system

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Wireless Alarm Host
Security Alarm Host
Type: Home Alarm
Type: Anti-Theft Alarm
Type: Smoke Detectors
Infrared Sensor Probe
Fire Alarm Host
Function: Networked
Usage: Door
Alarm Volume (within 1m): ≥110dB
Receive Frequency: 433.92MHz
Signal Transmission: Wireless Alarm
Working Mode: Active
Certification: CE
Application: Indoor
Working Principle: Electro-Optical Type
Networking Mode: GSM Dial-up
Transmission Mode: Wireless
Wiring Mode: Bus System
Sound and Magnetic System
Anti-theft Alarm System Approach: Active
Sound and Light Alarm
Point Control Alarm Detectors
Anti-Theft Alarm System Distance: Common Detectors
Photoelectric Smoke Style
Infrared Sensor Installation: Ceiling
Shaping Mode: Injection Mould
Surface Finish Process: Polishing
Mould Cavity: Multi Cavity
Process Combination Type: Single-Process Mode
Runner: Cold Runner
Design Software: UG
Installation: Fixed
Standard: DME
Customized: Customized
Infrared Sensor Probe Type: Inclination Sensor
Combustible Gas Detector Model: NA-300
Usage: Auto
Usage: Personal
Usage: Fire
Usage: Smoke
Usage: Window
Alarm Volume (within 1m): ≥80dB
Receive Frequency: 315MHz
RF Remote Control
Working Mode: Passive
Certification: RoHS
Certification: CCC
Certification: ISO
Certification: FCC
Certification: GS
Certification: TS16949
Application: Home
Communication Electronic Products
Application: Industry
Application: Special Equipment
Application: Household Appliances
Application: Commodity
Application: Home Use
Working Principle: Electromagnetic
Networking Mode: TCP/IP
Wiring Mode: Sub-Line System
Anti-Theft Alarm System Type: Infrared Alarm
Anti-Theft Alarm System Type: Smoke Alarms
Wire Alarm Detectors
Anti-Theft Alarm System Distance: Power Detector
Ionization Smoke Style
Infrared Sensor Installation: Embedded Wall
Infrared Temperature Sensor

Sourcing guidance for Wireless Fire Alarm System

What are the key technical specifications to consider when selecting a wireless fire alarm system for commercial use?

Buyers should prioritize systems utilizing dual-band frequency (e.g., 433MHz and 868MHz) to minimize signal interference. Ensure the system supports Mesh Networking technology, which allows detectors to relay signals, significantly extending the transmission range (ideally >200 meters in open areas). Additionally, verify that the battery life of sensors exceeds 3-5 years and that the control panel includes a GSM/GPRS or Wi-Fi backup module for redundant emergency notifications.

Which international compliance standards are mandatory for cross-border procurement of fire safety equipment?

Compliance is non-negotiable in this category. For the European market, products must carry the CE mark and comply with EN 54-25 standards specifically for wireless components. For the North American market, UL 268 (smoke detectors) or UL 864 (control units) certification is required. Additionally, ensure the manufacturer follows ISO 9001 quality management systems to guarantee consistent production reliability across large batches.

How does the integration capability of a wireless system impact long-term ROI?

A high-quality wireless fire alarm system should offer API or SDK integration to connect with existing Building Management Systems (BMS) or security platforms. Look for systems that support addressable identification, allowing the central station to pinpoint the exact location of a fire. This reduces false alarm response costs and facilitates easier maintenance, as the system can report specific device faults or low-battery statuses automatically.

Cross-Border Procurement & Risk Management for Fire Safety Systems

What are the primary risks when importing wireless electronic safety devices?

The most significant risk is frequency regulation non-compliance. Different countries have strict laws regarding radio frequency usage; importing a system that operates on a restricted local frequency can lead to customs seizure or legal penalties. Always confirm the RF (Radio Frequency) test reports match the destination country's telecommunications standards (e.g., FCC for the US, RED for the EU).

How should I negotiate quality assurance and after-sales support with Chinese suppliers?

When sourcing via Made-in-China.com, negotiate for a warranty period of at least 24 months. Request a 0.5% to 1% spare parts allowance (extra sensors or mounting brackets) to be included in the bulk shipment to cover immediate replacements. For large-scale projects, insist on technical remote support or video training for your local installation team to ensure the system is commissioned correctly.

What are the best practices for secure transactions and shipping for sensitive electronics?

Utilize Trade Assurance or secure payment terms that link fund release to the passing of a third-party pre-shipment inspection (PSI). Since these systems contain lithium batteries, they are classified as Dangerous Goods (UN3481) for air freight. Ensure the supplier provides the correct MSDS (Material Safety Data Sheet) and UN38.3 test reports to avoid shipping delays or hazardous materials surcharges.

Related queries