Spd class ii (20ka 40ka)
I have found results from1000+products and200+suppliers aboutSpd class ii (20ka 40ka)
Type 2 PV DC SPD 1500V 40ka Class II Surge Protective Device for Solar Combiner Box
Sp5-40 Surge Protection Device T2 Class Surge Arrester SPD 40ka
Sp5-80 Lightning Surge Protector SPD 80ka Continuous Voltage 460V 3p 4p or 3p+N
Rdf1-DC1500 Surge Protection for Solar DC System Max. PV Voltage DC1500V SPD
Rdf1-DC200 DC Type Surge Protection for Solar PV System Max PV Voltage 200V, 600V, 690V, 1500V SPD
Lyd1-C40 L-N 385/ N-PE 255 20ka-40ka 3p+Npe SPD Surge Protective Device
Solar DC SPD 2p 3p 1000V 1200V PV Surge Protector Lyd1-PV1000
Lyd1-C40 385V 20ka-40ka 3p+Npe SPD Surge Protective Device
Reyun DC SPD Lyd1-PV1000 DC 3pole Surge Protection for Photovoltaic
Lyd1-C40 DC Surge Protection Device 40ka SPD for 24V DC Power Supply System
Surge Protector DC 24V 2p 18mm SPD for PV Solar Surge Protective Device Lyd1-C40
Solar System SPD 20Ka 40Ka Voltage Suppressor Solar Lightning System Device Power Dc Surge Arrester
On-Grid PV System Class II 1000V Solar DC Rapid Shutdown Compatible SPD Lightning Voltage Protector
TUV T1+T2 3p 1500V DC Protection Device SPD for Solar System Lightning Protection
Single Pole 40ka 275V AC Surge Protector Device AC SPD
40ka 275V AC SPD Solar Power Photovoltaic Surge Protector Device for Lightning Protection
4p 40ka 275V AC Type 2 Low Voltage Surge Protector Device SPD
Solar PV Surge Protection 40ka 2p 600V DC Surge Protector Device SPD
OEM 1p+N 385V AC 40ka AC SPD Lightning Surge Protector Device
Ly1-C40 2p 40ka 500V DC SPD Solar System Surge Protective Device
Factory 20-40ka Surge Protector 3p 1000V SPD T1+T2 Solar Power
Hot Sale Three Phase DC 1500V Surge Protective Device SPD
3p+Npe/4p SPD DIN Rail 20-40ka SPD Surge Protection for AC System
36mm 4p SPD 40ka White Surge Protection Device for Thunder Protection
Sourcing guidance for SPD Class II (20kA 40kA)
What are the key technical specifications to consider when selecting a Class II SPD?
When sourcing a Class II Surge Protective Device (SPD), you must prioritize the Nominal Discharge Current (In) of 20kA and the Maximum Discharge Current (Imax) of 40kA. Ensure the Voltage Protection Level (Up) is compatible with the insulation strength of the equipment you are protecting; typically, for 230/400V systems, a Up ≤ 1.5kV is standard. Additionally, verify the Maximum Continuous Operating Voltage (Uc) to ensure it exceeds your network's peak voltage to prevent premature degradation.
Which international compliance standards are mandatory for global distribution?
For cross-border trade, the product must strictly adhere to IEC 61643-11, which is the international standard for low-voltage surge protective devices. For the European market, CE marking and RoHS compliance are essential. If you are exporting to North America, look for UL 1449 4th Edition certification. Always request third-party test reports from accredited labs like TUV, VDE, or KEMA to validate the claimed kA ratings.
How do I evaluate the internal safety components of the SPD?
The core component is the Metal Oxide Varistor (MOV). High-quality SPDs should feature thermal disconnection mechanisms to safely disconnect the device from the circuit at the end of its life, preventing fire hazards. Look for units with a visual status indicator (Green for OK, Red for Replace) and consider models with remote signaling contacts (dry contacts) for integration into building management systems.
What are the typical usage scenarios for 20kA/40kA Class II SPDs?
These devices are primarily designed for secondary protection in sub-distribution boards. They are installed downstream of Class I protectors to safeguard sensitive electronic equipment such as computers, telecommunication systems, and industrial PLC controllers. They are ideal for residential, commercial, and industrial environments where indirect lightning strikes or switching overvoltages are a risk.
Cross-Border Procurement & Risk Management for Electrical Components
How can I mitigate the risk of receiving counterfeit or sub-standard electrical goods?
Electrical components carry high liability. You should conduct a factory audit or hire a third-party inspector to verify the production line. On Made-in-China.com, prioritize Audited Suppliers who have undergone on-site verification. Always request a pre-shipment sample and perform a 'destructive test' to confirm the internal MOV size matches the technical datasheet.
What are the best practices for negotiating with Chinese SPD manufacturers?
Focus on the quality-to-price ratio rather than just the lowest price. Ask for the brand of the MOV used inside the device, as this accounts for most of the cost. Negotiate warranty terms of at least 2-5 years, and ensure the supplier agrees to a Quality Assurance Agreement where they bear the cost of replacements and shipping if the failure rate exceeds 1% within the first year.
What shipping precautions should be taken for sensitive electrical protectors?
SPDs contain ceramic and plastic components that can crack under heavy impact. Ensure the supplier uses double-wall corrugated export cartons and individual inner boxes for each unit. For bulk sea freight, specify palletization with shrink-wrap to prevent moisture ingress, which can compromise the insulation resistance of the electrical components.
How do I ensure transaction security during the international payment process?
Utilize Trade Assurance services provided by platforms like Made-in-China.com to protect your payment until the goods are confirmed to be shipped. For large orders, consider a Letter of Credit (L/C) or a staggered payment plan (e.g., 30% deposit, 70% against the Bill of Lading) to maintain leverage over the supplier until production is complete.