Rcbo price
I have found results from10000+products and3000+suppliers aboutRcbo price
High Performance AC RCBO for Household Electrical Safety
Type B RCBO for Photovoltaic New Energy Charging Piles (B-Type RCCB)
Factory Price RCBO Overload Protection 2pole Type a AC 30mA Dpn RCBO
Dz47le RCBO Electric Breaker with Good Quality and Best Price
Factory Price 230V Overcurrent Protection RCCB AC 63A 1p+N 3p+N 230/400V RCBO
Factory 40A Residual Current Operator Circuit Breaker Price 16A 25A 32A RCBO
Factory Price 25A 32A Circuit 40A 6ka 50/60Hz Electronic Breaker 1p+N RCBO
Good Price 1.2 Nm 1p+N Compact for Electrical Panels 230V Electromagnetic Energy Efficient RCBO Breaker
Manufacture Flame Retardant Circuit Breaker Leakage Electromagnetic Price 6ka 40A AC RCBO
Factory Price 50/60Hz 25A Residual Current Operator Leakage Circuit Breaker RCBO in Electrica
a, AC Type Circuit Breaker RCBO with CE, CB, SAA Certificate
RCBO Electronic Type with Overcurrent Protection Circuit Breaker RCD +MCB
Factory for Sale Prices Concessions Stro7-40 Series Residual Current Circuit Breaker RCBO
New Type 3ka IEC1009 230V 1p+N RCBO with Factory Price
Singi Sg65le-63 4p+N Factory Supply Earth Leakage Breaker Overcurrent Protection RCBO Price
Singi Swmle-100 1p+N Leakage Circuit Breaker 100A ELCB RCCB/RCBO Price
Singi Dz30le-32 1p+N C Type 3ka 6-32A Elce Price Miniature Circuit Breakers 1p RCBO 30mA
Air 1-4p Singi MCB 6-63A RCBO Circuit Breaker with Factory Price Sc65le-63
Factory Price MCB 1-4p Singi Circuit Breaker Miniature Electrical Breakers RCBO Sg65le-63
Circuit Breaker Price MCB Singi Electrical Breakers RCBO with Good Service Sg65le-63
C or D 1-4p Singi Circuit Breaker Price RCBO Sg65le-63
Miniature Circuit Breaker RCBO with Competitive Price Knln6-63
Electromagnetic RCBO with Overload Protection Knbl1-32
30mA Standard IEC61009-1 & IEC62423 RCD 40A 80A B Type RCBO
Elbo RCBO 1p+N 1 Module 30mA Residual Current Overload Protection 6A to 40A DIN
Sourcing guidance for Rcbo Price
How to choose the right RCBO based on technical specifications?
Selecting an RCBO requires matching the device to your specific electrical load and safety requirements. Key factors include Rated Current (In), typically ranging from 6A to 63A, and Rated Residual Operating Current (IΔn), where 30mA is the standard for personnel protection and 100mA/300mA is used for fire protection. You must also verify the Breaking Capacity (Icn), usually 6kA or 10kA, to ensure the device can safely interrupt a fault without exploding. Additionally, choose the correct Tripping Curve (B, C, or D): Type B is for resistive loads, Type C is the most common for general commercial/residential use, and Type D is for high-inductive loads like motors.
What are the essential compliance standards for global RCBO sourcing?
To ensure legal entry and safety in international markets, RCBOs must adhere to strict standards. For the European market, IEC/EN 61009-1 is the primary product standard, and products must carry the CE mark. For the UK, UKCA is required. If exporting to Australia, SAA certification and RCM marking are mandatory. For North American markets, look for UL 1053 or UL 489 compliance. Always request valid test reports from accredited third-party labs (like TUV, Intertek, or SGS) rather than relying solely on manufacturer-issued certificates.
How does the 'Type' of residual current sensing affect the price and application?
The sensing technology significantly impacts the cost. Type AC RCBOs are the most economical but only detect sinusoidal AC leakages. Type A is increasingly becoming the minimum requirement in many countries as it detects both AC and pulsating DC components, common in modern electronics. Type B RCBOs are the most expensive as they detect high-frequency AC and smooth DC leakages, making them essential for EV charging stations and solar PV installations. Choosing the wrong type can lead to 'blinding' the breaker, rendering it useless during a fault.
What physical attributes indicate a high-quality RCBO?
A high-quality RCBO should feature a flame-retardant shell (UL94-V0 grade) to prevent fire spread. Look for silver alloy contacts which provide superior conductivity and arc resistance compared to pure copper. The internal copper coil should be of high purity to ensure precise magnetic tripping. Additionally, check for a clear status indicator window (Red/Green) and a robust 'Test' button mechanism, which should be operated monthly by the end-user to ensure mechanical integrity.
Cross-Border Procurement Risks and Strategies for RCBOs
How can I mitigate the risk of receiving counterfeit or sub-standard electrical components?
Electrical components are high-risk items. To mitigate risk, conduct a factory audit or hire a third-party inspector to verify the production line. Use Made-in-China.com's 'Audited Supplier' reports to check the manufacturer's business license and production capacity. Always request a pre-shipment inspection (PSI) where a random sample is tested for 'Trip Time' and 'Trip Current' using a calibrated RCD tester before the final balance is paid.
What are the best negotiation strategies for bulk RCBO orders?
When negotiating, focus on the Total Cost of Ownership (TCO) rather than just the unit price. Ask for tiered pricing (e.g., 500, 2000, 5000 units) and negotiate for spare parts (1-2% extra units) to cover potential RMAs. If you are a long-term buyer, negotiate for customized laser marking (OEM) of your brand on the housing, which adds value to your retail offering without significantly increasing the unit cost.
What should I consider regarding international shipping and customs for circuit breakers?
RCBOs are heavy and dense, so sea freight is usually the most cost-effective for bulk orders. Ensure the supplier provides the correct HS Code (typically 853620) to avoid customs delays or incorrect duty applications. Because these are safety devices, customs in the destination country may request Declarations of Conformity (DoC); ensure your supplier provides these documents in English and that they match the branding on the physical product.
How can I ensure transaction security when dealing with overseas suppliers?
Never send full payments upfront to unknown suppliers. Utilize secure payment terms such as Letters of Credit (L/C) for very large orders or Escrow-based payment services provided by reputable platforms like Made-in-China.com. This ensures that funds are only released to the supplier once you have confirmed the shipment and documentation meet the agreed-upon standards.





























