Hydrophobic membrane filter
I have found results from9000+products and3000+suppliers aboutHydrophobic membrane filter
Sintered PE Pes PSU PPS Hydrophobic Porous Tubular PVDF and Pes Membrane Tube Filter
Lab Hydrophobic Syringe Membrane Filter 0.22um 0.45um 13mm 25mm 33mm Nylon PTFE PVDF RC GF Syringe Filter
Diameter Pore Size 0.22μm Hydrophobic Polypropylene Nylon Disc Membrane Filters 47 mm
10" X 69mm Hydrophobic PTFE Membrane Filter Cartridge 0.2micron Filter with 222/226/Fin/DOE
Hydrophobic PTFE0.2um Membrane Filter for Gas Air Fermentation Tank and Storage Tank Breathers
Hydrophobic PTFE Filter Membrane Vent Enhanced Steaming Resistance Fine Chemical Filtration
Hydrophobic PTFE 0.22um 10inch Membrane Filter for Compressed Air Filtration
Manufacturer Hydrophobic PTFE Pleated Filter Cartridge Vent Filter Membrane Filter for Air Filtration
Lab Filtration Sampling Hydrophilic Hydrophobic PTFE Membrane Filter
Lab Sterile Hydrophobic Pes Membrane 0.22um/0.45um Syringe Filter
Labfil Sterile 33mm PVDF Hydrophobic Membrane Lab Syringe Filters
Labfil 13mm PTFE Hydrophobic Membrane Micron 0.22um 0.45um Filters
Darlly Hydrophobic PTFE Membrane 0.1 Micron Pleated Filter Element for Compressed Air
Hydrophobic PTFE Membrane Syringe Filters 0.22um with Od 25mm Non-Sterile, 100PCS/Pack
10-Inch Hydrophobic PTFE Membrane Filter for Mushroom Growth
OEM 20 Inch Natural Hydrophobic PTFE Membrane Filter Cartridge for Fermentation Air Exhaust Filtration
5 Inch Hydrophobic PTFE Membrane Air Sterilizing Capsule Filter
Dimeter 13mm/25mm Disposable Hydrophobic PTFE Membrane Syringe Filters
Wholesale Laboratory HPLC Use 0.22um Pore Micro 25 mm Diameter Hydrophobic PTFE Membrane Syringe Filters
Darlly Hydrophobic PTFE / Hydrophilic Pes Membrane 0.22um Pleated Mini Junior Cartridge Filter Elements
Air Purification Filter 0.1/0.22/0.45 Um 5-40 Inch Hydrophobic Micron PTFE Membrane Pleated Vent Filter Cartridge
25mm 0.22 Micron Hydrophobic PTFE Membrane Disposable Syringe Filter
10" Code 7, Hydrophobic PTFE Membrane 0.2 Micron Pleated Cartridge Filters 0.22 Micron for Ethanol Filtration
Sourcing guidance for Hydrophobic Membrane Filter
What are the key technical specifications to consider when selecting a hydrophobic membrane filter?
When sourcing hydrophobic membrane filters, you must prioritize pore size (typically 0.1μm to 5.0μm) and material compatibility. Common materials include PTFE (Polytetrafluoroethylene), which offers the highest chemical resistance, and PVDF (Polyvinylidene Fluoride). Ensure the Water Entry Pressure (WEP) is high enough to prevent liquid penetration in venting applications, and verify the Air Flow Rate to ensure it meets your system's throughput requirements.
Which compliance standards are essential for medical and laboratory-grade filters?
For medical or pharmaceutical use, filters must meet USP Class VI Plastics tests for biocompatibility. If the product is intended for the US market, FDA 21 CFR 177 compliance for food and drug contact is mandatory. For European markets, ensure the supplier adheres to REACH and RoHS regulations. Additionally, look for ISO 13485 certification if the filters are components for medical devices.
How do usage scenarios dictate the choice of membrane support material?
Hydrophobic membranes are often fragile and require a support layer (backing) like Polyester (PET) or Polypropylene (PP). For high-temperature sterilization (autoclaving), PET is preferred due to its thermal stability. For chemical filtration, a pure PTFE membrane without backing or with a chemically inert support is necessary to avoid degradation and extractable contamination.
What performance benchmarks ensure long-term reliability in industrial venting?
Reliability is measured by Bubble Point testing to ensure membrane integrity and bacterial retention efficiency (BRE), which should be >99.99% for sterile venting. For outdoor sensors or automotive components, check the IP Rating (e.g., IP67 or IP68) to guarantee protection against dust and water immersion while maintaining gas permeability.
Cross-Border Procurement & Risk Management for Membrane Filters
What are the primary risks when sourcing technical membranes from overseas suppliers?
The biggest risk is batch-to-batch inconsistency, which can lead to system failures. To mitigate this, require a Certificate of Analysis (COA) for every shipment. Another risk is counterfeit materials; ensure the supplier is a verified manufacturer on Made-in-China.com and request scanning electron microscopy (SEM) images of the membrane structure to verify pore uniformity.
How should I negotiate quality assurance and return policies with international suppliers?
Negotiate a Quality Agreement that defines 'defective' based on specific metrics like flow rate deviation (>15%) or integrity test failure. Use Trade Assurance services to secure your payment. For high-value bulk orders, insist on a pre-shipment inspection (PSI) by a third party like SGS or Intertek to verify specifications before the balance payment is made.
What logistics and storage precautions are necessary for hydrophobic membranes?
Membranes are sensitive to electrostatic discharge (ESD) and environmental contaminants. Ensure the supplier uses double-layer anti-static packaging and vacuum sealing. During shipping, avoid high-pressure environments that could compromise the microporous structure. Upon arrival, store them in a controlled cleanroom environment with stable temperature and humidity to prevent premature aging of the polymer.
How do international trade policies affect the importation of filtration technology?
Check the HS Code (typically 5911.90 or 8421.99) to determine applicable import duties. Be aware of Export Control Lists if the membranes have 'dual-use' applications (industrial vs. military). Always clarify Incoterms (e.g., DAP or CIF) to understand where the risk transfers, especially since specialized filters can be easily damaged during customs inspections if not handled properly.