High pressure sodium ballast
I have found results from1000+products and500+suppliers aboutHigh pressure sodium ballast
600W Electronic Dimmable Ballast Black Color for Grow Light
HPS 1000 Watt De Fixture with HID Ballast Reflector Lamp for Grow Light
Magnetic Ballast 600W/1000W 220V-240V/50Hz for Grow Light High Quality
Greenhouse Dimmable Electronic Ballast 600W Mh/HPS
HID Magnetic Ballast 600W/1000W 220V-240V/50Hz for Grow Light
HPS 600W Electronic Dimmable Ballast Black Color for Grow Light
Greenhouse Dimmable Digital Ballast 600W Mh/HPS White
HPS 1000 Watt De Fixture with HID Ballast Reflector Lamp
HPS 600W Electronic Digital Dimmable Ballast Black Color
2kw Halide Lamp High Pressure Sodium Electronic UV Ballast for Printing Press Machine
Sailon High Quality 10W Pre-Heat Ultraviolet Lamp Electronic Ballast
EPS51-425-40L 110V/230V Electronic Ballast for Ultraviolet Lamp
T8 Electronic Ballast 2X30W Dual Lamp Fluorescent Tube Ballast for Commercial Lighting
Ultraviolet UV Fish Aggregating Lamp Ballast for Squid Saury Light Attracting
70W 150W 250W 400W Cwa Electromagnetic Ballast (transformer)
20W~40W T5 UV Germicidal Lamp Electric Ballast with Cord
Electronic Ballast Sx05-800-2/75u 95W-150W 800mA Ballasts for UV Air Sterilizer Snxin or OEM
Ballast for UV Lamp Suppliers 220V 10W-55W Ballast with Sound Alarm Air Purification and Water Treatment
Good Sale Light Alarm 4/10/12/16/25/30/40/55W Ballast Electronic Ballasts for UV Germicidal Lamps
UV Disinfecting Light Use Electronic Ballast 800mA Sx05-800-2-75u 95W-150W Ballasts One Year Guarantee
UV Ballast Electronic 2.1-2.2A 320W Lamp Electronic Ballasts for Gphva1554t5l High Output UVC Lamp Tube
Pl1-425-90 40W 95W 425mA 120V 230V UV Lamp Power Supply Electronic Ballast with CE
Sourcing guidance for High Pressure Sodium Ballast
What are the key technical specifications to consider when selecting an HPS ballast?
Buyers must prioritize wattage compatibility (e.g., 250W, 400W, 600W, 1000W) to match the lamp, and choose between Magnetic (Core & Coil) or Electronic (Digital) types. Electronic ballasts are preferred for their higher energy efficiency, dimmable functions, and lower heat output. Ensure the Input Voltage (e.g., 120V, 240V, or 277V) aligns with the local power grid, and check for a Power Factor >0.95 to minimize energy waste.
Which international compliance standards are mandatory for HPS ballasts?
For the North American market, UL or ETL listing is essential for safety and insurance compliance. For European markets, CE marking and RoHS compliance are mandatory to ensure the product meets health, safety, and environmental protection standards. Additionally, FCC Part 18 certification is critical for electronic ballasts to ensure they do not cause electromagnetic interference (EMI) with other electronic devices.
How does the thermal management of a ballast affect its lifespan?
HPS ballasts generate significant heat; therefore, heat dissipation design is vital. Look for units with extruded aluminum housings and cooling fins. High-quality electronic ballasts should feature internal thermal protection that automatically shuts down the unit if temperatures exceed safe limits (usually around 90°C). Proper thermal management can extend the ballast's life to over 30,000 to 50,000 hours.
What are the usage scenarios and functional requirements for industrial-grade HPS ballasts?
In commercial horticulture (greenhouses), ballasts must have an IP64 or higher rating to resist dust and moisture. For street lighting, look for ballasts with high surge protection (at least 6kV-10kV) to withstand lightning strikes and grid fluctuations. Functional features like 'Soft Start' technology are recommended to reduce inrush current and extend the life of the HPS lamps.
Cross-Border Procurement Risks and Strategies for HPS Ballasts
How can I mitigate the risk of receiving substandard electrical components?
Always request a sample for lab testing before placing a bulk order. Use third-party inspection services like SGS or Intertek to conduct a Pre-Shipment Inspection (PSI). Specifically, ask the inspector to verify the internal capacitor quality and transformer winding material (copper is superior to aluminum for conductivity and durability).
What is the best strategy for negotiating with HPS ballast suppliers on Made-in-China.com?
Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for a longer warranty period (3-5 years) and clarify the RMA (Return Merchandise Authorization) policy. For large orders, request tiered pricing where the unit cost drops by 5-10% as volume increases, and insist on Trade Assurance to secure your payment until delivery is confirmed.
What are the logistics and shipping precautions for heavy electrical equipment?
Magnetic ballasts are heavy; for these, Sea Freight (LCL or FCL) is the most economical method. Ensure the supplier uses palletized packaging with moisture-proof wrapping and reinforced corner protectors. For electronic ballasts, which are sensitive to vibration, specify anti-static foam cushioning in the inner boxes to prevent circuit board damage during transit.
How do I ensure transaction security and policy alignment in international trade?
Verify that the supplier's Business License matches their bank account details to avoid payment fraud. Ensure the Harmonized System (HS) Code (typically 8504.10 for ballasts) is correctly declared on the Commercial Invoice to avoid customs delays or incorrect duty applications. Stay updated on anti-dumping duties that may apply to electrical components from specific regions.





























