Yokogawa pressure transmitter
I have found results from1000+products and500+suppliers aboutYokogawa pressure transmitter
Yokogawa Ejx110A Differential Pressure Transmitter Dpharp, Hart, Sil2/3, High Accuracy
Yokogawa Eja110e Hart Differential Pressure Transmitter for Flow Level Measurement
Ejx110A9 Yokogawa High Precision Smart Differential Pressure Transmitter with Sil2 for Industrial Process Flow Measurement
Original Japan Yokogawa Eja120e Eja430e Eja530e Eja130e Eja310e High Accuracy Pressure Transmitter
Original Japan Yokogawa Ejx910A Fjx930A Multivariable Differential Pressure Transmitter
Yokogawa Eja110e Differential Pressure Transmitter Dpharp, Hart, Sil2/3 ±0.055% Accuracy
Yokogawa Eja115e Integral Orifice Differential Pressure Transmitter Low Flow, Dpharp, Hart, Sil2/3
Yokogawa Eja440e High Gauge Pressure Transmitter 4-20mA Hart
Yokogawa Eja210A High Precision Flange Mounted Liquid Level Differential Pressure Transmitter for Industrial Process Control
Yokogawa Eja110A 4-20mA Hart Differential Pressure Transmitter for Oil Gas Chemical Industrial Process Control
Yokogawa Eja130e High Static Pressure Differential Pressure Transmitter for Liquid Gas Steam Application
Yokogawa Ejx530A 4-20mA Hart Gauge Pressure Transmitter for Liquid Gas Steam Application
Yokogawa Eja118e Diaphragm Sealed Differential Pressure Transmitter Remote Seal
Yokogawa Eja530A/Eja530e/Ejx530A Pressure Sensor Transmitter
High-Precision Yokogawa Eja530e & Ejx210A Differential Pressure Transmitter
Sourcing guidance for Yokogawa Pressure Transmitter
What are the key technical specifications to consider when selecting a Yokogawa Pressure Transmitter?
When sourcing Yokogawa pressure transmitters, particularly the EJA-E and EJX-A series, you must verify the Reference Accuracy (typically ±0.055% or ±0.04% for high-end models). Ensure the Measurement Range (Span) aligns with your process requirements to avoid signal clipping. Additionally, confirm the Wetted Parts Material (e.g., Hastelloy C-276, Monel, or Tantalum) to ensure chemical compatibility with your specific medium and prevent corrosion.
Which communication protocols and output signals are standard for these devices?
Most industrial applications require the 4-20 mA DC signal with HART protocol. However, for advanced automation, you should check if the supplier provides FOUNDATION Fieldbus, PROFIBUS PA, or ISA100 Wireless options. Ensure the transmitter's software revision is compatible with your existing Distributed Control System (DCS) or PLC to guarantee seamless integration.
What compliance and safety certifications are mandatory for hazardous environments?
For oil, gas, or chemical industries, the transmitter must have Explosion-proof or Intrinsically Safe certifications such as ATEX, IECEx, or FM/CSA. Furthermore, if the device is used in safety-instrumented systems, verify it meets SIL 2/3 (IEC 61508) standards for functional safety. Always request the Certificate of Compliance and the Calibration Certificate from the manufacturer or authorized distributor.
How does the DPharp digital sensor technology benefit long-term operations?
Yokogawa’s unique DPharp (Differential Pressure High Accuracy Resonance Peak) sensor provides both static pressure and differential pressure measurements simultaneously. This technology offers superior long-term stability (e.g., 0.1% of URL per 10 years), which significantly reduces the frequency of re-calibration and lowers the Total Cost of Ownership (TCO) compared to traditional analog sensors.
Cross-Border Procurement & Risk Management for Yokogawa Transmitters
How can I verify the authenticity of Yokogawa products from international suppliers?
The market for high-end instrumentation often faces risks of refurbished or counterfeit units. Always check the Serial Number with Yokogawa’s official database. Prioritize suppliers on Made-in-China.com who are Audited Suppliers or have Gold Member status. Request high-resolution photos of the nameplate and the original factory packaging before shipment.
What are the risks associated with lead times and international logistics for precision instruments?
Precision transmitters are sensitive to vibration and static electricity. Ensure the supplier uses anti-static packaging and shock-absorbent materials. Given global supply chain fluctuations, confirm the Lead Time in writing; standard models may take 2-4 weeks, while customized diaphragms can take 8-12 weeks. Use Incoterms like CIF or DAP to ensure the seller handles insurance during the transit phase.
What strategies should be used for price negotiation in B2B bulk orders?
Negotiation should be based on Volume Tiers. For orders exceeding 20 units, aim for a 10-15% discount off the standard list price. Discuss Project-Based Pricing if you are a regular integrator. Additionally, negotiate for extended warranty periods (e.g., 18-24 months instead of the standard 12) to mitigate the risk of defects discovered after long-distance shipping.
How do I ensure transaction security and compliance with trade policies?
Utilize Secure Payment services provided by Made-in-China.com to ensure funds are only released upon confirmation of receipt. Be aware of Export Control Regulations (Dual-Use goods); ensure the supplier provides the correct HS Code (typically 902620) to avoid customs delays or seizures. Always verify if there are Anti-dumping duties or specific import tariffs between the shipping origin and your country.





























