Heat recovery units
I have found results from100000+products and40000+suppliers aboutHeat recovery units
Direct Expansion Type Heat Recovery Fresh Air Air Handling Unit, Connected Wih Condensing Unit/Vrf
Energy-Efficient Modular Air Handling Unit with Heat Recovery Technology
Air Source Heat Pump with Heat Recovery Unit Commercial Inverter Air-Cooled Modular Chiller (or heat pump unit) Test Lab
Dx/Chilled Water Heat Recovery Fresh Air Handling Unit (CE China Factory)
Ahu Ventilation Clean 100% Fresh Air Handling Unit with Heat Recovery (inverter)
Heat and Humidity Exchanger Quiet Operation Air Filtration HVAC System Energy Recovery Unit
Holtop Dx Purification Heat Recovery Saving Energy Ahu Air Handling Units Leading Technologies.
Heat Recovery Air Handling Unit Rooftop Packaged Unit
Factory Price OEM Ahu Air Handling Units with Heat Recovery
Midea Modular Heat Recovery Fresh Ahu Air Handling Unit HVAC System
Supply Waste Heat Recovery Unit for Ventilation System
Heat Recovery Fresh Exhaust Air Ventilation Equipment System Air Handing Unit with HEPA
HVAC Solution Energy Saving Air Handling Unit for School Hall Climate Equipment Heat Recovery for Hospital Use Metal
Fresh Air Ventilation System Residential Heat Recovery Hrv Air Handling Unit Ahu
10000CMH Heat Pump Heat Recovery Fresh Air Handling Unit
Commercial Medical Ahu Fresh Air Handling Unit with Heat Recovery
Fresh Air Ventilation Recuperator Heat Recovery Unit with Heat Exchanger Core
Energy Saving Counterflow Recuperator Heat Recovery Unit for Home & Commercial
Heat Recovery Air Handling Unit Rooftop Packaged HVAC Unit
Single Room Heat Recovery Ahu 4000 Cfm Chilled Water Air Handling Unit
Central HVAC Heat Recovery Heating Ahu System Air Handling Unit High Quality High-Efficiency
Rooftop Package AC Unit for HVAC with Heat Recovery Energy Saving
Air Cooled Reversible Rooftop Package Unit with Wheel Heat Recovery
Energy Efficient Heat Recovery Rooftop Air Handling Unit
HVAC System Heat Energy Recovery Medical Surgery Clean Room Dx Ahu Rooftop Packaged Air Handling Unit
55000cfm Customized Plate Core Heat Recovery Filtration Air Handling Unit Ahu
Advanced Variable Frequency Air Handling Unit with Heat Recovery
Advanced Air Handling Units with Heat Recovery Technology
Sourcing guidance for Heat Recovery Units
What are the key technical specifications to consider when selecting a Heat Recovery Unit for commercial use?
When sourcing Heat Recovery Units (HRV) or Energy Recovery Units (ERV), the most critical metric is the Heat Exchange Efficiency, which should ideally be above 70%. You must specify the Airflow Capacity (m³/h or CFM) to match the building's volume. Additionally, prioritize units with EC (Electronically Commutated) motors for lower energy consumption and low noise levels (under 45dB for indoor units). For humid climates, ensure the unit features an enthalpy exchanger to manage both sensible and latent heat.
Which international compliance standards and certifications are mandatory for these products?
To ensure safety and market entry, verify that the supplier holds CE marking for the European market or UL/ETL certification for North America. Look for ISO 9001 for manufacturing quality management and ISO 14001 for environmental standards. Furthermore, high-quality units should comply with ErP 2018 (Energy-related Products) directives in the EU to guarantee high energy efficiency and carbon footprint reduction.
How do I evaluate the filtration and air quality capabilities of a Heat Recovery Unit?
The filtration system is vital for indoor air quality (IAQ). Ensure the unit supports HEPA H13 filters or at least MERV 13 ratings to capture fine particulate matter (PM2.5). Check if the supplier offers integrated CO2 or VOC sensors that allow the unit to adjust airflow automatically based on real-time air quality, which significantly enhances operational efficiency and user comfort.
What maintenance requirements should be discussed with the supplier before purchasing?
Inquire about the accessibility of the heat exchange core and filters; tool-free access is preferred for routine maintenance. Ask for the expected lifespan of the motors and the exchange core (typically 10-15 years). Ensure the supplier provides a comprehensive O&M (Operation and Maintenance) manual and confirms the availability of replacement filters and spare parts for at least 5 years post-purchase.
Cross-Border Procurement & Risk Management for HVAC Equipment
What are the primary risks when importing heavy HVAC equipment like Heat Recovery Units?
The main risks include shipping damage to sensitive internal fins and voltage/frequency incompatibility. Always confirm the local electrical standards (e.g., 220V/50Hz vs 110V/60Hz) before production. To mitigate physical damage, mandate reinforced plywood crate packaging rather than standard cardboard boxes, and consider third-party pre-shipment inspections to verify functional performance.
How can I negotiate better terms and ensure transaction security with Chinese suppliers?
Utilize secure payment methods and look for suppliers on Made-in-China.com who have the 'Audited Supplier' badge. When negotiating, leverage bulk order forecasts to secure a 10-15% discount on unit prices. Request a 30% deposit and 70% balance payment after providing a successful third-party inspection report (e.g., SGS or Intertek) but before the goods leave the factory.
What logistics strategies are recommended for shipping these units to international markets?
Due to the volume and weight, Sea Freight (FCL or LCL) is the most economical method. For large projects, use FOB (Free On Board) terms to maintain control over the shipping costs and choose your own freight forwarder. Ensure the HS Code (typically 8419 50) is correctly declared to avoid customs delays and check for any anti-dumping duties or specific trade tariffs applicable to HVAC equipment in your country.





























